Ordering Code for Push-Pull Cable Controls
314 (6) - L - TT - 3 - 144 (AP)314 | (6) | L | TT | 3 | 144 | (AP) |
| |
| |
| |
| |
| |
| |
| |
Letter | End Rod Thread | |
V | 10-32 | |
M | 5/16 UNF | |
L | 1/4-28 UNF | |
H | 3/8 UNF |
End Fitting Combination
T - Threaded Swivil
G - Groved Swivel
Cable Travel, In Inches (1", 2", 3", 4", 5", 6")
Length, In Inches +/-.25 Inches
Suffix Letters For Additional Features
(Use Only If Requesting Optional Features)
N - End Rod Jam Nuts (2 each)
A - Combination of N and W
S - Stamp with Cablecraft and Customer Part Number
W - Extra Shakeproof Washers on Conduit Ends
P - Stamp with Customer Part Number
M - Metic End Rods (Optional)
V - M5 x .8
L - M6 x 1.0
H - M8 x 1.25
H - M10 x 1.5
Low Friction-EXT and Utility Cables Design Criteria
Efficiency
Efficiency factor ratings are for comparative purposes and may vary due to length, rate of travel, direction of travel, bend radius and temperature.
To Compare Efficiency;
Input force = Output load (lbs) x total degrees of bend x efficiency factor + output load.
Efficiency Factors:
Low Friction - EXT .0012
Utility .002
Backlash
Nominal Backlash = Backlash factor x total degrees of bend.
Backlash Factors:
VLD .00015
LD .00020
MD .00025
HD .00030
Temperature range: -65 to +230 degree F
MINIMUM | DUTY BEND. RAD. |
VLD | 2" |
LD | 3" |
MD | 5" |
HD | 6" |