Ordering Code for Push-Pull Cable Controls
314 (6) -
L - TT - 3 - 144 (AP)
314 |
(6) |
L |
TT |
3 |
144 |
(AP) |
| Control Type |
| Seal
Options |
| Cable
Size |
| End
Fitting Combination |
| Cable
Travel |
|
Length |
|
Suffix Letters |
Control Type
Low Friction-EXT
313 - With Stainless Steel End Rods
314 - With Stainless Steel Support Tubes, and End Rods
315 - All Exposed Fittings/parts are Stainless Steel
Utility
173 - With Stainless Steel End Rods
174 - With Stainless Steel Support Tubes, End Rods and Innermember Armor
175 - All Exposed Fittings/parts are Stainless Steel Plus Stainless Innermember Armor
Seal Options
(Use This Number Only If Requesting Optional Seals)
6 Model 6 Wiper Seal, Optional on all Controls
Cable Size
|
Letter |
End Rod Thread |
|
V |
10-32 |
|
M |
5/16 UNF |
|
L |
1/4-28 UNF |
|
H |
3/8 UNF |
End Fitting Combination
T - Threaded Swivil
G - Groved Swivel
Cable Travel, In Inches (1", 2", 3", 4", 5", 6")
Length, In Inches +/-.25 Inches
Suffix Letters For Additional Features
(Use Only If Requesting Optional Features)
N - End Rod Jam Nuts (2 each)
A - Combination of N and W
S - Stamp with Cablecraft and Customer Part Number
W - Extra Shakeproof Washers on Conduit Ends
P - Stamp with Customer Part Number
M - Metic End Rods (Optional)
V - M5 x .8
L - M6 x 1.0
H - M8 x 1.25
H - M10 x 1.5
Push-Pull Cable Specifications
(Click to see pop up chart of specifications)
Low Friction-EXT and Utility Cables Design Criteria
Efficiency
Efficiency factor ratings are for comparative purposes and may
vary due to length, rate of travel, direction of travel, bend radius and
temperature.
To Compare Efficiency;
Input force = Output load (lbs) x total degrees of bend x efficiency factor +
output load.
Efficiency Factors:
Low Friction - EXT .0012
Utility .002
Backlash
Nominal Backlash = Backlash factor x total degrees of bend.
Backlash Factors:
VLD .00015
LD .00020
MD .00025
HD .00030
Temperature range: -65� to +230� F
MINIMUM |
DUTY BEND. RAD. |
VLD |
2" |
LD |
3" |
MD |
5" |
HD |
6" |
|
|